HydroFixx up to 25.8 m³/h / 113.6 gpm
600 kW / 2,047.3 MBH at ΔT 20 K
The manifold with integrated hydraulic separator
Chamber size: | 200/200 |
Heating water flow rate: | 25.8 m³/h / 113.6 gpm |
Output at ∆T 20 K: | 600 kW / 2,047.3 MBH |
Largest connection: | DN 100 / 4" |
Boiler connection: | up to DN 125 / 6" |
Pipe distance (OC) | 300 mm, 350mm, variable / 11.8", 13.8", variable |
Product description
Combined flow and return manifold with chambers arranged adjacent to each other, separated by sinusoidal partition wall, with horizontally welded-on hydronic junction located directly below.
Consisting of square profiles S235. The HydroFixx is pressure-tested and primed at the factory.
- The supply from/to the heating boiler is possible both from the top onto the compact manifold and from the bottom to the hydronic junction.
- Heating circuit connections as threaded and / or flanged connectors PN 6 / PN 16 and aligned to the height of the shut-off valves.
- With downward-running sludge trap with 1" desludging sleeve.
Accessories
Stand bracket
For chamber size
| Bottom plate | Head plate | Adjustable in height |
---|---|---|---|
[mm] | [mm] | [mm] | [mm] |
120/120 to 200/200 |
150 x 150 | 120 x 120 | from 270 to 340 |
280/320 to 500/550 | 200 x 200 |
150 x 180 |
from 270 to 340 |
Soundproof and zinc-plated, consisting of bottom plate with stand pipe and head plate
with guide pipe incl. connecting screws, adjustable in height.
Wall bracket
For chamber size
| Head plate |
Outreach |
---|---|---|
[mm] | [mm] | [mm] |
120/120 to 200/200 |
120 x 120 | 300 |
280/320 to 500/550 | 150 x 180 |
500 |
Soundproof and zinc-plated, consisting of wall panel for screw fastening,
bracket and head plate.
Thermal insulation
For chamber size
| PUR foam in coarse grain aluminium casing | PUR foam in galvanized sheet steel casing | Mineral wool in galvanized sheet steel casing |
---|---|---|---|
[mm] | [Insulation thickness in mm] | [Insulation thickness in mm] | [Insulation thickness in mm] |
120/120 to 200/200 |
60 | - | 100 |
280/320 to 500/550 | - | 60 | 100 |
In compliance with EnEV 2014 consisting of half shells with end pieces and cutouts for all nozzles
Magnetite separation module - Flange
Attention: All magnetite separation modules in flange-type design are not suitable for retrofitting.
For separation of ferromagnetic substances.
Consisting of an additional flanged connector DN 125 PN 6, equipped with sealing, screws, nuts, and blind flange fitted with magnetite filter bars, depending on the size of the selected HydroFixx.
Draining gutter
Made of galvanized sheet steel, size: 100/125/100 mm with 2" drain sieve.
Fastening devices: Stand bracket, galvanized (height adaptable by customer), wall bracket, galvanized
(max. outreach 200 mm)
Identification plate
Made of galvanized sheet steel with transparent cover for three-line label for screw fixing to the thermal insulation. Size: 100 x 50 mm, colours: red for flow line / blue for return line
Technical data
Heating water flow rate
|
Output at
ΔT 20 K |
Manifold chamber
| Water quantity Manifold | Water quantity junction |
Heat transfer at 70°/50°C |
Return flow boost |
Wall thickness | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
[m³/h] | [gpm] | [kW] | [MBH] | [Width / Height] | [l/rm] | [gal/rm] | [l/rm] | [gal/rm] | [kW] | [MBH] | [%] | [K] | [mm] | [in inch] |
25.8 | 113.6 | 600 | 2,047.3 | 200/200 | 21.5 | 5.7 | 14.5 | 3.8 | 4.3 | 14.7 | 1.0 | 0.2 | 4 | 0.2 |