HydroFixx up to 70 kW / 238.8 MBH
The manifold with integrated hydronic junction
incl. EPP insulation and wall bracket
Chamber size: | 80/80 |
Heating water flow rate: | 3 m³/h / 13.2 gpm |
Output at ∆T 20 K: | 70 kW / 238.8 MBH |
Pipe distance (OC) | 125 mm / 4 15/16" |
Product description
Combined flow and return manifold with chambers arranged adjacent to each other, separated by sinusoidal partition wall, with horizontally welded-on hydraulic separator located directly below.
Consisting of square profiles S235. The HydroFixx is pressure-tested and zinc-plated at the factory.
- Connection to / from heat generator by means of 1 1/2" NPT downwards, two coupling sleeves 1/2" for sensor and emptying.
- Heating circuit connections by means of flat-sealing rim with 1 1/2" cap nut for mixer.
Accessories
Thermal insulation, included in the set
For chamber size
| EPP foam (black) |
---|---|
[mm] | [Insulation thickness in mm] |
80/80 |
45 |
120/120 | 63 |
In compliance with EnEV 2014 consisting of half shells with end pieces and cutouts for all nozzles.
Wall bracket, included in the set
For chamber size
|
Outreach up to manifold centre |
---|---|
[mm] | [mm] |
80/80 |
160 |
120/120 | 230 |
Soundproof and zinc-plated, consisting of wall panel for screw fastening and bracket (2 wall brackets are required for each HydroFixx).
Maintenance box - Magnetite separation module
Enables desludging with pressurized system. Consisting of section tube 80x60, material S235, connection: 2x G 1 ½“. Equipped with desludging nozzle and ball valve ½“ and magnetic rod screwed into the thermwell. For attachment to the boiler return line beneath the manifold.
Set components: EPP insulation in compliance with EnEV, ball valve, magnetite filter cartridge
Adapter piece (flat sealing)
For reduction of 1 1/2" cap nuts to 1 1/4".
Identification plate
Made of galvanized sheet steel with transparent cover for three-line label for screw fixing to the thermal insulation. Size: 100 x 50 mm, colours: red for flow line / blue for return line
Technical data
Output at
ΔT 20 K |
Manifold chamber
|
Number of heating circuits
| Heating water throughput rate | Length | Water quantity |
Wall thickness | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
[kW] | [MBH] | [Width / Height] | [HK] | [m³/h] | [gpm] | [mm] | [in inch] | [l] | [gal] | [mm] | [in inch] |
70 | 238.8 | 80/60 | 2 | 3.0 | 13.2 | 460 | 18.1 | 2.5 | 0.7 | 2.5 | 0.1 |
70 | 238.8 | 80/60 | 3 | 3.0 | 13.2 | 710 | 28.0 | 3.9 | 0.7 | 2.5 | 0.1 |